Rotation Hand Controller: Difference between revisions

From Project Apollo - NASSP
Jump to navigation Jump to search
imported>Tschachim
(→‎Power supply: Clarfication)
imported>Tschachim
(New control handling)
 
(2 intermediate revisions by the same user not shown)
Line 1: Line 1:
The '''Rotation Hand Controller (RHC)''' provides the capability of manual control of spacecraft rotation in either direction about each axis. Also the RHC may be used for manual thrust vector control (see [[SPS]]). In the real CSM there were two identical Rotation Hand Controllers, in Project Apollo - NASSP both are simulated simultaneously by using one joystick or Orbiter's attitude controls (joystick, keyboard) when configured with the [[Launchpad Configuration Options]].
The '''Rotation Hand Controller (RHC)''' provides the capability of manual control of spacecraft rotation in either direction about each axis. Also the RHC may be used for manual thrust vector control (see [[SPS]]). In the real CSM there were two identical Rotation Hand Controllers, in Project Apollo - NASSP both are simulated simultaneously by using one joystick or Orbiter's attitude controls (joystick, keyboard) as configured with the [[Launchpad Configuration Options]].
 
== Quickstart Mode ==
 
In ''[[First Steps#Quickstart Mode|Quickstart Mode]]'' the RHC isn't used, but the [[CSM RCS]] and the [[SPS]] engine are controlled by Orbiter directly as for example in the Delta-glider including the navmodes (killrot etc.), attitude and engine control by MFDs etc. So this article applies in ''Virtual AGC Mode'' only, but optionally Orbiter attitude control can be disabled with the [[Launchpad Configuration Options]] for ''Quickstart Mode'', too.


== RHC commands ==
== RHC commands ==
Line 25: Line 29:
=== Direct power ===
=== Direct power ===


The RHC breakout switches are powered with DC power if one or both of the ROT CONTR PWR DIRECT 1 or 2 switches {{Panel label|name=B}} are switched to MNA/MNB or the ROT CONTR PWR DIRECT 1 switch is switched to MNA or the ROT CONTR PWR DIRECT 2 switch is switched to MNB<cite>III</cite>.
The RHC direct switches are powered with DC power if one or both of the ROT CONTR PWR DIRECT 1 or 2 switches {{Panel label|name=B}} are switched to MNA/MNB or the ROT CONTR PWR DIRECT 1 switch is switched to MNA or the ROT CONTR PWR DIRECT 2 switch is switched to MNB<cite>III</cite>.
 
== Joystick and Orbiter's controls support ==
 
Rotational control is provided by joysticks or Orbiter's attitude controls. In case of joysticks, the [[Launchpad Configuration Options]] allow the use of one or two joysticks. If only one joystick is configured, it acts as RHC or [[THC]] depending on Orbiter's attitude control mode. The axes of the real RHC are the same as the axes of a typical 3-axes joystick.
 
With the '''"Use Orbiter controls as RHC/THC"''' option enabled in the [[Launchpad Configuration Options]], the Orbiter controls (keyboard, joystick etc. as you have configured it) are used as input for the RHC while in Orbiter's rotational attitude mode. In this case Orbiter's joystick axes and keys assignments to the rotational movements of the spacecraft apply.
 
When a digital control like a keyboard is used as RHC input, an attitude command is simulated as full deflection, i.e. both the brakeout and the direct switches are closed and the transducers produce full signal strength.
 
With this option disabled, rotational thruster firing with the [[w:numeric keypad|numeric keypad]] or a joystick enabled in Orbiter is possible but unrealistic. In this case Orbiter controls the thrusters directly without using the auto or direct thruster control coils, so this is still working without electrical power, disabled coils etc. The RCS thrusters still need proper fuel supply though.


<biblio force=false>
<biblio force=false>
Line 41: Line 35:
  #II The ROT CONTR PWR NORMAL 1 switch receives AC power from the SCS AC1 circuit breakers on panel 8, the ROT CONTR PWR NORMAL 2 switch receives AC power from the SCS ECA/TVC AC2 circuit breakers on panel 8. For both switches the [[ECA]] needs to be powered, too.
  #II The ROT CONTR PWR NORMAL 1 switch receives AC power from the SCS AC1 circuit breakers on panel 8, the ROT CONTR PWR NORMAL 2 switch receives AC power from the SCS ECA/TVC AC2 circuit breakers on panel 8. For both switches the [[ECA]] needs to be powered, too.
  #III The ROT CONTR PWR DIRECT 1 switch receives DC power from either both the SCS CONTR/DIRECT 1 MNA and MNB circuit breakers on panel 8 when switched to MNA/MNB or from the SCS CONTR/DIRECT 1 MNA circuit breaker on panel 8 only when switched to MNA. The ROT CONTR PWR DIRECT 2 switch receives DC power from either both the SCS CONTR/DIRECT 2 MNA and MNB circuit breakers on panel 8 when switched to MNA/MNB or from the SCS CONTR/DIRECT 2 MNB circuit breaker on panel 8 only when switched to MNB.
  #III The ROT CONTR PWR DIRECT 1 switch receives DC power from either both the SCS CONTR/DIRECT 1 MNA and MNB circuit breakers on panel 8 when switched to MNA/MNB or from the SCS CONTR/DIRECT 1 MNA circuit breaker on panel 8 only when switched to MNA. The ROT CONTR PWR DIRECT 2 switch receives DC power from either both the SCS CONTR/DIRECT 2 MNA and MNB circuit breakers on panel 8 when switched to MNA/MNB or from the SCS CONTR/DIRECT 2 MNB circuit breaker on panel 8 only when switched to MNB.
  #[[References]]
  #[[References]]  
</biblio>
</biblio>



Latest revision as of 20:28, 30 July 2008

The Rotation Hand Controller (RHC) provides the capability of manual control of spacecraft rotation in either direction about each axis. Also the RHC may be used for manual thrust vector control (see SPS). In the real CSM there were two identical Rotation Hand Controllers, in Project Apollo - NASSP both are simulated simultaneously by using one joystick or Orbiter's attitude controls (joystick, keyboard) as configured with the Launchpad Configuration Options.

Quickstart Mode

In Quickstart Mode the RHC isn't used, but the CSM RCS and the SPS engine are controlled by Orbiter directly as for example in the Delta-glider including the navmodes (killrot etc.), attitude and engine control by MFDs etc. So this article applies in Virtual AGC Mode only, but optionally Orbiter attitude control can be disabled with the Launchpad Configuration Options for Quickstart Mode, too.

RHC commands

The command switches of the RHCAOH

The axes of the real RHC are the same as the axes of of a typical 3-axes joystick, so if a joystick is configured it can be used as usual. In case of Orbiter's attitude controls they are used as configured in Orbiter. Within the RHC there are three command sources per axis:

  • Breakout Switches - A switch closure occurs whenever the RHC is moved 1.5° from its null position (about 12% of total deflection). Separate switches are provided in each axis and for each direction of rotation. These six breakout switches are used to provide: command signals to the CMC, SCS minimum impulse and acceleration commands, BMAG cage signals and proportional rate command enabling.
  • Transducers - Transducers produce AC signals proportional to the RHC displacement from the null position. These signals are used to command spacecraft rotation rates during SCS proportional rate mode and to command SPS engine gimbal position during Manual Thrust Vector Control (MTVC).
  • Direct Switches - Direct switches will close whenever the RHC is moved a nominal 11.5° from its null position (about 92% of total deflection). Direct switch closure will produce acceleration commands through the RCS direct solenoids.

Power supply

Location of RHC switches

An RHC needs to be powered before it can be used, of course. Since the simulated RHC is both RHC 1 and 2, the simulated RHC is working if one or both RHCs are powered. The power for the direct switches and direct RCS thruster solenoids is independant of the normal power supply.

Normal power

The RHC breakout switches are powered with DC power if one or both of the ROT CONTR PWR NORMAL 1 or 2 switches A are switched to AC/DCI. The transducers are powered with AC power if one or both of the ROT CONTR PWR NORMAL 1 or 2 switches A are switched to AC/DC or ACII.

Direct power

The RHC direct switches are powered with DC power if one or both of the ROT CONTR PWR DIRECT 1 or 2 switches B are switched to MNA/MNB or the ROT CONTR PWR DIRECT 1 switch is switched to MNA or the ROT CONTR PWR DIRECT 2 switch is switched to MNBIII.

<biblio force=false>

#I The ROT CONTR PWR NORMAL switches receive DC power from both the SCS CONTR/AUTO MNA and MNB circuit breakers on panel 8. 
#II The ROT CONTR PWR NORMAL 1 switch receives AC power from the SCS AC1 circuit breakers on panel 8, the ROT CONTR PWR NORMAL 2 switch receives AC power from the SCS ECA/TVC AC2 circuit breakers on panel 8. For both switches the ECA needs to be powered, too.
#III The ROT CONTR PWR DIRECT 1 switch receives DC power from either both the SCS CONTR/DIRECT 1 MNA and MNB circuit breakers on panel 8 when switched to MNA/MNB or from the SCS CONTR/DIRECT 1 MNA circuit breaker on panel 8 only when switched to MNA. The ROT CONTR PWR DIRECT 2 switch receives DC power from either both the SCS CONTR/DIRECT 2 MNA and MNB circuit breakers on panel 8 when switched to MNA/MNB or from the SCS CONTR/DIRECT 2 MNB circuit breaker on panel 8 only when switched to MNB.
#References 

</biblio>

External Links