Template:Prelaunch checklist

From Project Apollo - NASSP
Revision as of 10:39, 19 October 2006 by imported>Tschachim
Jump to navigation Jump to search

When it's possible, the original Apollo documentation is used for the checklists. Steps, which are not possible at the moment, are denoted in grey. Additionally there are checklists in Word file format in the Doc\Project Apollo - NASSP\Check List directory of your installation. Procedural steps in this section are presented in tabular form and in sequence they occure during the mission. The following is a detailed explanation of the columnar data presented in the tabulated lists:

Apollo 15 launch checklistA15_LAUNCH_CHECK
Time This column contains the mission time the procedure is to be done. Sometimes there's no fixed time when to do a procedure, in that case the time is left out.
Procedure The procedure is a group of steps or overall tasks involved in performing a complete function or operation. It often consists of controls the astronauts have to toggle or display readings that have to be checked. See CSM panels for more informations.
Panel The panel number of a particular switch or display for easier panel navigation.
Remarks Any useful comment. Please notice especially differences to the original function, bugs or other issues.

Spacecraft systems activation

In Project Apollo - NASSP the Saturn prelaunch checklist starts at 3 hours before launch with the backup crew in the spacecraft. At first some of the spacecraft's systems have to be activated.

Time Procedure
Panel
Remarks
-03:00:00
C/W system activation
   
C/W POWER - 1 (up)
  MASTER ALARM pb/lt (3) - on,
  push
 
 
2
 
 




The suit compressor alarm is normal.

CMC power up
 
cb G/N COMPUTER MNA - close
cb G/N COMPUTER MNB - close
 
 
5
 
Activation of the command
module computer.

{{ #if: |

 
V37E 00E
  P00
 
If prog alarm, check if alarm code 1520
"V37 request not permitted at this time"
by V05N09E, then RSET and retry V37E 00E
 
V35E
  F 88 88
V37E 00E
 
V16 N65E
  16 65
V37E 00E
2
Run program P00



This can happen every
V37 request.



Light test



Shows time since power-up,
check time synchronization
with Orbiter.

|

 
Wait until DSKY light test complete
  STBY lt - on
PRO
  STBY lt - out
Key N00E
  P00
  NO ATT lt - on
Key V34E
Key V16 N33E
2
Light test isn't historically
correct.



Run program 0,
the AGC idling program.
IMU is not turned on.

Show launch countdown
(not historically correct).

}}

 
IMU power up
 
cb G/N IMU HTR MNA - close
cb G/N IMU HTR MNB - close
cb G/N IMU MNA - close
cb G/N IMU MNB - close
 
  {{ #if: |NO ATT lt - on (90 sec) |NO ATT lt - off }}
  {{ #if: |NO ATT lt - off | }}
 
 
5
 
 
 
 
2

Activation of the inertial
measurement unit.

Backup crew prelaunch checks

C&WS status check

With the first procedure the caution and warning system is checkedAOH2.

Glycol loop checks

Next the primary and secondary water-glycol coolant loops are checked and the primary water-glycol coolant loop is activated. The grey lines indicate displays or controls which are not available at the moment, please ignore these steps.

Standby inverter checks

Time Procedure Panel Remarks
  C/W NORM - BOOST 2 This is not mentioned in the Apollo Operations HandbookAOH2, but otherwise the C/W lights during the inverter check won't work.

Panels checks

Next some checks regarding the panel displays and controls have to be done and a few but very important devices have to be turned on. We begin at panel 325, which is to the left of the left side panel.

Time Procedure
Panel
Remarks
 
PRIM GLY TO RAD vlv - NORM
325
 
 
AUTO RCS (16) - OFF
SECS LOGIC (both) - OFF
SECS PYRO ARM (2) - SAFE
cb pnl 8 - all closed except
  cb CM RCS HTRS (both) - open
  cb FLOAT BAGS (all) - open
  cb SECS LOGIC (2) - open
  cb SECS ARM (2) - open
8
 
 
EDS PWR - OFF
TVC SERVO PWR (both) - OFF
FDAI/GPI POWER - BOTH
LOGIC 2/3 PWR - on (up)
ELEC PWR - GDC/ECA
SIG CONDR/DR BIAS PWR (both) - AC1 or AC2
BMAG PWR (both) - WARMUP
7



Turn on both FDAIs.

Turn on GDC and ECA.
Powers RJ/EC. Switches should
not be set on same bus.

 
CMC ATT - IMU
ACCEL - check (+1 G)
FDAI SCALE - 5/1
FDAI SEL - 1/2
FDAI SOURCE - CMC
ATT SET - GDC
MAN ATT ROLL - RATE CMD
MAN ATT PITCH - ACCEL CMD
MAN ATT YAW - RATE CMD
LIM CYCLE - OFF
ATT DBD - MIN
RATE - HI
THC PWR - on (up)
RHC PWR NORM (both) - AC/DC
RHC PWR DIR (both) - OFF
 
SC CONT - SCS
CMC MODE - FREE
BMAG MODE (3) - RATE 2
ATT SET TW (3) - R 162°, P 90°, Y 0°
 
ELS LOGIC - OFF
ELS AUTO - AUTO
CM RCS LOGIC - OFF
CM PRPLNT DUMP - OFF
CM PRPLNT PURG - off (down)
IMU CAGE - off (down)
 
α/Pc IND sw - α
α/Pc ind - zero
LV IND/GPI sw - GPI
EVNT TMR START - ctr
EVNT TMR RSET - up (ctr)
1
 
 














Activate Trans. Contr. Pwr.
Activate Rot. Contr. Pwr.






These are the nominal values
for a 72° launch azimuth.
Guarded.



Guarded.
Guarded.
Guarded.

Switch to α.


Event timer not counting. Timer resets and starts automatically when lift-off occurs.

 
SUIT CAB ΔP ind - > + 2.0 inH2O
O2 FLOW ind - 0.4 ± 0.1 lb/hr
 
PROBE EXTD/REL tb (2) - gray
PROBE (3) - OFF
 
RCS status check
  SM RCS He 1 tb (4) - bp
  SM RCS He 2 tb (4) - bp
  SM RCS PRIM PRPLNT tb (4) - bp
  SM RCS SEC PRPLNT tb (4) - bp
 
EDS AUTO - OFF
CSM/LM FNL SEP (both) - off (down)
CM/SM SEP (2) - off (down)
SIVB/LM SEP - off (down)
PRPLNT DUMP - AUTO
2 ENG OUT sw - AUTO
LV RATES sw - AUTO
TWR JETT (both) - AUTO
LV GUID sw - IU
LV STAGE - OFF
XLUNAR INJECT - INJECT
MN REL - off (down)
2
 
 
 
 




Gray indicates probe fully
extended or retracted.


Barber pole indicates
valves are closed.





Guarded.
Guarded.
Guarded.




Guarded.
Guarded.
Guarded.

Guarded.
 
FC 1 PUMPS - AC1
FC 2 & 3 PUMPS - AC2
MN BUS TIE (2) - OFF
BAT CHGR - AC1
cb pnl 5 - all closed
5
 
 
 
GLY PUMPS - 1 AC1
SUIT COMPR (both) - OFF
cb pnl 4 - all closed
4
 
 

Prelaunch alignment

Now the prelaunch programs of the CMC are started, the DSKY is used for that. During prelaunch the IMU platform, also called stable member (SM), is aligned to launch position.

IMU prelaunch alignmentTrainingGN

{{ #if:

|

Time Procedure
Panel
Remarks
 
Start program P01
 
Key V37E 01E
NO ATT lt - on
  Course align IMU
  NO ATT lt - off
  Change to P02
 
 
2
After starting P01 "Prelaunch or service initialization program" the IMU changes to course align mode and drives the stable member to prelaunch position.

Then it changes automatically to P02 "Prelaunch or service gyro compassing program". Because the AGC commands during P02 are very small you can't see them at the FDAI, but you can monitor the IMU gimbal angles with V16 N20E.

 
Optional check/change of launch azimuth
 
Key V78E
  F 06 29

R1: Launch azimuth

 
To proceed press PRO, to change:
Key V21E
  F 21 29
Key +XXXXXE
  F 06 29
Key PRO
  Pulse gyros...
  The AGC did a prelaunch alignment for the launch azimuth as it is stored in the scenario. If you like, you can check or change it. This is done with verb 78, the DSKY shows the present launch azimuth. Press PRO to continue without changing, with verb 21 you could "load component 1 into R1" and change the launch azimuth in the format +XXX.XX°. Press PRO to confirm the new setting. Press CLR to clear a wrong input.
 
... to new launch position.
  After pressing PRO the AGC changes the attitude of the stable member with gyro pulses to the new launch azimuth.

|

Time Procedure
Panel
Remarks
 
Start program P01
 
Key V37 N01E
  NO ATT lt - on
  NO ATT lt - off
 
 
2
 

Start P01 "Prelaunch or service initialization program".

 
  Change to P02
  F 06 29
PRO
  Verb 06, noun 29 shows the desired launch azimuth in format XXX.XX°, press PRO to confirm.
 
  F 06 44
PRO
  Noun 44 shows shows in R1 the desired apoapsis and in R2 the periapsis altitude, both in format XXXX.X m, press PRO to confirm.
 
  F 06 33
Key V16E
  16 33
  Noun 33 shows time to lift-off, hours in R1, minutes in R2 and seconds in R3. Verb 16 monitors the countdown, that means the DSKY updates the time every 2 seconds. (not historically correct)

}} The computer and the IMU are running and ready for launch.

Test

{{ #if: |Virtual AGC |NASSP AGC }}

Test End

<biblio force=false>

  1. References

</biblio>