Rotation Hand Controller: Difference between revisions

From Project Apollo - NASSP
Jump to navigation Jump to search
imported>Tschachim
(Work in progress...)
imported>Tschachim
(Work in progress...)
Line 14: Line 14:


When a digital control like a keyboard is used as RHC input, an attitude command is simulated as full deflection, i.e. both the brakeout and the direct switches are closed and the transducers produce full signal strength.
When a digital control like a keyboard is used as RHC input, an attitude command is simulated as full deflection, i.e. both the brakeout and the direct switches are closed and the transducers produce full signal strength.
== Power supply ==
[[Image:RHC_switch_location.jpg|thumb|right|Location of RHC switches]]
An RHC needs to be powered before it can be used, of course. Since the simulated RHC is both RHC 1 and 2, the simulated RHC is working if either or both RHCs are powered. The power for the direct switches is independant of the normal power supply.
=== Normal power ===
The RHC breakout switches are powered with DC power if either or both of the ROT CONTR PWR NORMAL 1 or 2 switches {{Panel label|name=A}} are switched to AC/DC<cite>I</cite>. The transducers are powered with AC power if either or both of the ROT CONTR PWR NORMAL 1 or 2 switches {{Panel label|name=A}} are switched to AC/DC or AC<cite>II</cite>.
=== Direct power ===
The RHC breakout switches are powered with DC power if either or both of the ROT CONTR PWR DIRECT 1 or 2 switches {{Panel label|name=B}} are switched to MNA/MNB or the ROT CONTR PWR DIRECT 1 switch is switched to MNA or the ROT CONTR PWR DIRECT 2 switch is switched to MNB<cite>III</cite>.


<biblio force=false>
<biblio force=false>
  #I The TRANS CONTR PWR switch receives power from the SCS CONTR/AUTO MNA/B circuit breakers on panel 8  
  #I The ROT CONTR PWR NORMAL switches receive DC power from both the SCS CONTR/AUTO MNA and MNB circuit breakers on panel 8.
#II The ROT CONTR PWR NORMAL 1 switch receives AC power from the SCS AC1 circuit breakers on panel 8, the ROT CONTR PWR NORMAL 2 switch receives AC power from the SCS ECA/TVC AC2 circuit breakers on panel 8. For both switches the [[ECA]] needs to be powered, too.
#III The ROT CONTR PWR DIRECT 1 switch receives DC power from either both the SCS CONTR/DIRECT 1 MNA and MNB circuit breakers on panel 8 when switched to MNA/MNB or only from the SCS CONTR/DIRECT 1 MNA circuit breaker on panel 8 when switched to MNA. The ROT CONTR PWR DIRECT 2 switch receives DC power from either both the SCS CONTR/DIRECT 2 MNA and MNB circuit breakers on panel 8 when switched to MNA/MNB or only from the SCS CONTR/DIRECT 2 MNB circuit breaker on panel 8 when switched to MNB.
  #[[References]]
  #[[References]]
</biblio>
</biblio>

Revision as of 19:07, 4 June 2008

The Rotation Hand Controller (RHC) provides the capability of manual control of spacecraft rotation in either direction about each axis. Also the RHC may be used for manual thrust vector control (see SPS). In the real CSM there were two identical Rotation Hand Controllers, in Project Apollo - NASSP both are simulated simultaneously by using one joystick or Orbiter's attitude controls (joystick, keyboard) when configured with the Launchpad Configuration Options.

RHC commands

The command switches of the RHCAOH

The axes of the real RHC are the same as the axes of a joystick, so if a joystick is configured it can be used as usual. In case of Orbiter's attitude controls they are used as configured in Orbiter. Within the RHC there are three command sources per axis:

  • Breakout Switches - A switch closure occurs whenever the RHC is moved 1.5° from its null position (about 12% of total deflection). Separate switches are provided in each axis and for each direction of rotation. These six breakout switches are used to provide: command signals to the CMC, SCS minimum impulse and acceleration commands, BMAG cage signals and proportional rate command enabling.
  • Transducers - Transducers produce AC signals proportional to the RHC displacement from the null position. These signals are used to command spacecraft rotation rates during SCS proportional rate mode and to command SPS engine gimbal position during Manual Thrust Vector Control (MTVC).
  • Direct Switches - Direct switches will close whenever the RHC is moved a nominal 11.5° from its null position (about 92% of total deflection). Direct switch closure will produce acceleration commands through the RCS direct solenoids.

When a digital control like a keyboard is used as RHC input, an attitude command is simulated as full deflection, i.e. both the brakeout and the direct switches are closed and the transducers produce full signal strength.

Power supply

Location of RHC switches

An RHC needs to be powered before it can be used, of course. Since the simulated RHC is both RHC 1 and 2, the simulated RHC is working if either or both RHCs are powered. The power for the direct switches is independant of the normal power supply.

Normal power

The RHC breakout switches are powered with DC power if either or both of the ROT CONTR PWR NORMAL 1 or 2 switches A are switched to AC/DCI. The transducers are powered with AC power if either or both of the ROT CONTR PWR NORMAL 1 or 2 switches A are switched to AC/DC or ACII.

Direct power

The RHC breakout switches are powered with DC power if either or both of the ROT CONTR PWR DIRECT 1 or 2 switches B are switched to MNA/MNB or the ROT CONTR PWR DIRECT 1 switch is switched to MNA or the ROT CONTR PWR DIRECT 2 switch is switched to MNBIII.


<biblio force=false>

#I The ROT CONTR PWR NORMAL switches receive DC power from both the SCS CONTR/AUTO MNA and MNB circuit breakers on panel 8. 
#II The ROT CONTR PWR NORMAL 1 switch receives AC power from the SCS AC1 circuit breakers on panel 8, the ROT CONTR PWR NORMAL 2 switch receives AC power from the SCS ECA/TVC AC2 circuit breakers on panel 8. For both switches the ECA needs to be powered, too.
#III The ROT CONTR PWR DIRECT 1 switch receives DC power from either both the SCS CONTR/DIRECT 1 MNA and MNB circuit breakers on panel 8 when switched to MNA/MNB or only from the SCS CONTR/DIRECT 1 MNA circuit breaker on panel 8 when switched to MNA. The ROT CONTR PWR DIRECT 2 switch receives DC power from either both the SCS CONTR/DIRECT 2 MNA and MNB circuit breakers on panel 8 when switched to MNA/MNB or only from the SCS CONTR/DIRECT 2 MNB circuit breaker on panel 8 when switched to MNB.
#References

</biblio>


This article is a stub. You can help Project Apollo - NASSP by expanding it.